Greater than two coexisting mutations in KRAS and NRAS identified in the circulating tumor DNA fraction of liquid biopsies by NGS and confirmed with ddPCR.

Authors

null

Hala Boulos

Tempus Labs, Chicago, IL

Hala Boulos , Robert Tell , Nike Beaubier , Richard Blidner

Organizations

Tempus Labs, Chicago, IL

Research Funding

No funding received
None

Background: Liquid biopsies are increasingly utilized as a non-invasive tool in precision oncology to assess tumor mutational profiles in order to select targeted therapies, detect treatment resistance, and monitor disease progression in cancer patients. Additionally, liquid biopsies may provide a more comprehensive representation of tumor heterogeneity than standard tissue biopsies. However, limitations such as scarcity of circulating tumor DNA (ctDNA) and/or variants at low frequencies can be technically challenging to detect by next-generation sequencing (NGS) assays. Here, we use NGS to detect greater than two KRAS/NRAS mutations coexisting in single samples at low variant allele frequencies (VAFs). Methods: The Tempus xF liquid biopsy NGS assay is designed to detect actionable oncologic targets spanning 105 genes in plasma. The assay was validated to reliably detect single-nucleotide variants at 0.25% VAF, indels and copy number variants at 0.5% VAF, and fusions at 1% VAF with 96.2%-100% specificity and 97.4%-100% sensitivity. Pre-designed digital PCR assays were modified to measure 10ng of cell-free DNA (cfDNA) on a droplet-digital PCR (ddPCR) platform. Results: Overall, we report 100% positive predictive value and high correlation between ddPCR results and xF VAF, as well as in individual variants, such as KRAS G12D. Unexpectedly, we detected more than two coexisting KRAS/NRAS mutations at a low VAF in the plasma samples. To orthogonally confirm these results, ddPCR was deployed to independently measure the presence of each cfDNA variant with a sensitivity of 0.09% VAF. Subsequent ddPCR analysis of all targeted variants were concordant with NGS results. Conclusions: The occurrence of multiple KRAS and NRAS mutations in a single sample is quite uncommon and may be falsely interpreted as an NGS artifact. However, verification of this phenomenon by ddPCR confirmed the validity of the NGS liquid biopsy approach. These results highlight the capability of the Tempus xF assay to detect low-frequency variants, including those that fall below the validated detection threshold, which is essential for the diagnosis of early disease.

Disclaimer

This material on this page is ©2024 American Society of Clinical Oncology, all rights reserved. Licensing available upon request. For more information, please contact licensing@asco.org

Abstract Details

Meeting

2020 ASCO Virtual Scientific Program

Session Type

Publication Only

Session Title

Publication Only: Developmental Therapeutics—Molecularly Targeted Agents and Tumor Biology

Track

Developmental Therapeutics—Molecularly Targeted Agents and Tumor Biology

Sub Track

Circulating Biomarkers

Citation

J Clin Oncol 38: 2020 (suppl; abstr e15563)

DOI

10.1200/JCO.2020.38.15_suppl.e15563

Abstract #

e15563

Abstract Disclosures

Similar Abstracts

Abstract

2024 ASCO Gastrointestinal Cancers Symposium

Association of candidate alterations with primary resistance to KRAS G12D targeting in colorectal cancer.

First Author: Khalid Jazieh